Sitelab's test method is very simple.  Using our disposable test kits, soil, sediment or groundwater samples are quickly prepared and analyzed in only a few minutes, as illustrated below:

 

Testing Soil?

Soil samples are weighed onto a digital scale and placed into a jar for extraction.

 
Testing Water?

Water samples are first shaken up, measured out and then poured into an extraction jar.

2. Add Solvent

Methanol solvent is measured out and then added to each jar. The extraction jars are shaken by hand for several minutes, giving the solvent ample time to dissolve and extract the hydrocarbons.

 

3. Filter Extract

A syringe is used to suck up the extract, which is then passed through a specialized filter to remove particulates and potential interferences.

 

4. Dilute Extract

Sitelab’s adjustable pipette is then used to dilute the extract into a second test tube for analysis, in order for the sample to be detected within the linear range of the calibration curve.

 

5. Test Sample

The sample is poured into a glass cuvette and  then placed into the analyzer for analysis.  After a few seconds, the sample's concentration is displayedFinal results are calculated by multiplying the reading by the dilution factor.

 

 